Decoupled power brake alerts
Browse 337 DPB alert codes and open an entry for its description and recorded conditions.
DPB alert codes
Showing 201–250 of 337
- DPB_a201 — Vehicle Speed Q Faulty DPB_a201_vehicleSpeedQFaulty Vehicle speed Qualifier Faulty.
- DPB_a202 — Vehicle Standstill Q Faulty DPB_a202_vehicleStandstillQFaulty Vehicle standstill Qualifier Faulty.
- DPB_a203 — ABS Not Available DPB_a203_ABSNotAvailable ABS Not available.
- DPB_a204 — CAN Undervoltage DPB_a204_CANUndervoltage replacement fault for NET undervoltage situation.
- DPB_a205 — NvM Write Cycle Exceed DPB_a205_NvMWriteCycleExceed Alert in case if write/Erase service is requested sporadically.
- DPB_a206 — OS Task Scheme Error DPB_a206_OSTaskSchemeError Task scheme error detected.
- DPB_a207 — Hydraulic Overvoltage DPB_a207_hydraulicOvervoltage This alert is not valid anymore.
- DPB_a208 — Pressure Sensor1 Short DPB_a208_pressureSensor1Short Pressure Sensor 1, line shorted to Supply or Interruption of Sensor ground or Sensor supply or Signal line.
- DPB_a209 — Pressure Sensor1 High DPB_a209_pressureSensor1High Pressure Sensor 1, Out of Range High.
- DPB_a210 — Pressure Sensor1 Low DPB_a210_pressureSensor1Low Pressure Sensor 1 Out of Range Low.
- DPB_a211 — Pressure Sensor1 Fault DPB_a211_pressureSensor1Fault Pressure Sensor 1 internal alert.
- DPB_a212 — Pressure Sensor1 Temp DPB_a212_pressureSensor1Temp Pressure Sensor 1, Temperature Out Of Range.
- DPB_a213 — Pressure Sensor1 Fault DPB_a213_pressureSensor1Fault Pressure Sensor 1, alert in SENT protocol.
- DPB_a214 — Pressure Sensor2 Short DPB_a214_pressureSensor2Short Pressure Sensor 2, line shorted to Supply or Interruption of Sensor ground or Sensor supply or Signal line.
- DPB_a215 — Pressure Sensor2 High DPB_a215_pressureSensor2High Pressure Sensor 2, Out of Range High.
- DPB_a216 — Pressure Sensor2 Low DPB_a216_pressureSensor2Low Pressure Sensor 2, Out of Range Low.
- DPB_a217 — Pressure Sensor2 Fault DPB_a217_pressureSensor2Fault Pressure Sensor 2, Sensor internal alert.
- DPB_a218 — Pressure Sensor2 Temp DPB_a218_pressureSensor2Temp Pressure Sensor 2, Temperature Out Of Range.
- DPB_a219 — Pressure Sensor2 Fault DPB_a219_pressureSensor2Fault Pressure Sensor 2, alert in SENT protocol.
- DPB_a220 — Excessive Boost Wakeups Detected DPB_a220_excessiveBoostWakeupsDetected ECU woke up repeatedly with ignition off. This hints at issues with vehicle-specific wake-up sources (e.g. door contact).
- DPB_a221 — Not Shutdown Right DPB_a221_notShutdownRight Plunger was not parked at its sleeping position at the previous postrun.
- DPB_a222 — Excessive Ecu Resets Detected DPB_a222_excessiveEcuResetsDetected An excessive number of ECU resets has occurred in a row during actuator initialization (before IPC completion).
- DPB_a223 — RAM Fault DPB_a223_RAMFault RAM alert.
- DPB_a224 — Brake Boost Lost DPB_a224_brakeBoostLost Brake boosting capability is lost in DPB system.
- DPB_a225 — U5 V Out Of Range DPB_a225_U5VOutOfRange U5V is out of range.
- DPB_a226 — U5 V Test Fault DPB_a226_U5VTestFault U5V voltage comparator test failed.
- DPB_a227 — Brake Fluid Loss DPB_a227_brakeFluidLoss Decoupled Power Brake (DPB) detects suspected brake fluid loss after running the Cyclic Volume Check (CVC). CVC can be identified by DPB_a314_runningCyclicVolumeCheck.
- DPB_a228 — Supply AS IC Init Fault DPB_a228_supplyASICInitFault Initial test/check for ASIC supply parts failed.
- DPB_a229 — IREF Out Of Range DPB_a229_IREFOutOfRange The ASIC internal current reference is out of range.
- DPB_a230 — OS Error Hook DPB_a230_OSErrorHook Operating System error (e.g. task overrun, invalid parameters for OS API).
- DPB_a231 — Stack Over Under Flow DPB_a231_stackOverUnderFlow Stack over- or underflow.
- DPB_a232 — System Error Hook DPB_a232_systemErrorHook Internal interrupt based system error.
- DPB_a233 — System Task Jitter DPB_a233_systemTaskJitter This alert is not valid anymore.
- DPB_a234 — System Task Over Run DPB_a234_systemTaskOverRun Runtime overload.
- DPB_a235 — UB6 Plausi Mon Fault DPB_a235_UB6PlausiMonFault UB6 to UBB plausible voltage divider drift alert (large deviation in the UB6 to UBB ratio).
- DPB_a236 — UB6 Supply Path Fault DPB_a236_UB6SupplyPathFault High ohmic UB6 path detected (Large deviation between UB6 & UBB during motor actuation).
- DPB_a237 — U C Voltage Divider Drift DPB_a237_uCVoltageDividerDrift UB_Valve to UBRD_INT plausi voltage divider drift alert (large deviation between UB_Valve to UBRD_INT voltage).
- DPB_a238 — Micro Register Fault DPB_a238_microRegisterFault An ADC register Bit flipped or is stucked.
- DPB_a239 — Micro Safety Fault DPB_a239_microSafetyFault micro controller safety logic has detected an alert.
- DPB_a240 — Micro Safety Logic Fault DPB_a240_microSafetyLogicFault Startup safety test detected an alert of uC safety logic.
- DPB_a241 — U C Safety Notification DPB_a241_uCSafetyNotification micro controller memory/peripheral guard has detected a violation event by an unauthorized busmaster.
- DPB_a242 — U C Safety Notification GRAM DPB_a242_uCSafetyNotificationGRAM micro controller memory guard has detected a GRAM guard violation event.
- DPB_a243 — Micro Supply Error DPB_a243_microSupplyError Voltage monitor of micro controller has detected an alert of the micro controller supply voltage.
- DPB_a244 — Valves Generic Fault DPB_a244_valvesGenericFault Continuous Monitoring of ASIC Configuration or Test Fault.
- DPB_a245 — Valve MV0 Fault DPB_a245_valveMV0Fault General ASIC-Valve-Driver-alert like, Dx-Loss, PGND-Loss, ADC_calfail_SPI, wrong Freewheeling state, Overtemperatue, Overcurrent detected.
- DPB_a246 — Valve MV5 Fault DPB_a246_valveMV5Fault General ASIC-Valve-Driver-issue like, Dx-Loss, PGND-Loss, ADC_calfail_SPI, wrong Freewheeling state, Overtemperatue, Overcurrent detected.
- DPB_a247 — Valve MV6 Fault DPB_a247_valveMV6Fault ASIC-Valve-Driver-issue, short between valve-coils/output channels detected or general alert like, Dx-Loss, PGND-Loss, Overtemperatue, Overcurrent detected.
- DPB_a248 — Valve MV61 Fault DPB_a248_valveMV61Fault General ASIC-Valve-Driver-issue like, Dx-Loss, PGND-Loss, ADC_calfail_SPI, wrong Freewheeling state, Overtemperatue, Overcurrent detected.
- DPB_a249 — Valve MV62 Fault DPB_a249_valveMV62Fault General ASIC-Valve-Driver-issue like, Dx-Loss, PGND-Loss, ADC_calfail_SPI, wrong Freewheeling state, Overtemperatue, Overcurrent detected.
- DPB_a250 — Valve MV7 Fault DPB_a250_valveMV7Fault General ASIC-Valve-Driver-issue like, Dx-Loss, PGND-Loss, ADC_calfail_SPI, wrong Freewheeling state, Overtemperatue, Overcurrent detected.