Skip to content

DPB_a235 — UB6 Plausi Mon Fault

Full alert identifier: DPB_a235_UB6PlausiMonFault

Alert description

UB6 to UBB plausible voltage divider drift alert (large deviation in the UB6 to UBB ratio).

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

Possible voltage divider drift alert (with respect to UBB and UB6 measurement). Ratio between UBB and UB6 is checked every specified time. alert is set if the ratio is within specified range.

Clear condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a235.

Browse all DPB alert codes