Skip to content

DPB_a236 — UB6 Supply Path Fault

Full alert identifier: DPB_a236_UB6SupplyPathFault

Alert description

High ohmic UB6 path detected (Large deviation between UB6 & UBB during motor actuation).

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

High ohmic path between UBB and UB6. During motor actuation: If UB6 is less than specified voltage and UBB minus UB6 is greater than specified voltage, then the alert shall be set.

Clear condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a236.

Browse all DPB alert codes