DPB_a228 — Supply AS IC Init Fault
Full alert identifier: DPB_a228_supplyASICInitFault
Alert description
Initial test/check for ASIC supply parts failed.
Potential impact
System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.
Set condition
Defect or deviation of ASIC configuration on software and hardware side. Test checks if the voltage regulator configuration of the ASIC matches the software configuration.
Clear condition
No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a228.