DPB_a228 — Supply AS IC Init Fault

Full alert identifier: DPB_a228_supplyASICInitFault

Alert description

Initial test/check for ASIC supply parts failed.

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

Defect or deviation of ASIC configuration on software and hardware side. Test checks if the voltage regulator configuration of the ASIC matches the software configuration.

Clear condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a228.

Browse all DPB alert codes