DPB_a240 — Micro Safety Logic Fault
Full alert identifier: DPB_a240_microSafetyLogicFault
Alert description
Startup safety test detected an alert of uC safety logic.
Potential impact
System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.
Set condition
Malfunction of the micro controller safety logic, During start up the safety logic (e.g. Flash/RAM ECC) of the micro controller is tested. If one of these tests fails RBuCSafetyLogicFault is reported.
Clear condition
No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a240.