Skip to content

DPB_a239 — Micro Safety Fault

Full alert identifier: DPB_a239_microSafetyFault

Alert description

micro controller safety logic has detected an alert.

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

micro controller safety logic detected an error (e.g. Flash/RAM ECC uncorrectable fault), If a micro controller alert is detected the ErrorPin is set by HW only reaction (no SW action) and an exception is issued.

Clear condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a239.

Browse all DPB alert codes