Skip to content

DPB_a243 — Micro Supply Error

Full alert identifier: DPB_a243_microSupplyError

Alert description

Voltage monitor of micro controller has detected an alert of the micro controller supply voltage.

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

Core voltage is out of range. In case the core voltage is out of range (over/under-voltage), the Core Voltage Monitor issues a reset. Once the core voltage is in range again, a alert will be reported.

Clear condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a243.

Browse all DPB alert codes