Decoupled power brake alerts
Browse 337 DPB alert codes and open an entry for its description and recorded conditions.
DPB alert codes
Showing 251–300 of 337
- DPB_a251 — Valve MV8 Fault DPB_a251_valveMV8Fault General ASIC-Valve-Driver-issue like, Dx-Loss, PGND-Loss, ADC_calfail_SPI, wrong Freewheeling state, Overtemperatue, Overcurrent detected.
- DPB_a252 — Valve MV81 Fault DPB_a252_valveMV81Fault General ASIC-Valve-Driver-issue like, Dx-Loss, PGND-Loss, ADC_calfail_SPI, wrong Freewheeling state, Overtemperatue, Overcurrent detected.
- DPB_a253 — Valve MV82 Fault DPB_a253_valveMV82Fault General ASIC-Valve-Driver-issue like, Dx-Loss, PGND-Loss, ADC_calfail_SPI, wrong Freewheeling state, Overtemperatue, Overcurrent detected.
- DPB_a254 — Valve MV9 Fault DPB_a254_valveMV9Fault General ASIC-Valve-Driver-issue like, Dx-Loss, PGND-Loss, ADC_calfail_SPI, wrong Freewheeling state, Overtemperatue, Overcurrent detected.
- DPB_a255 — Valve Relay Short DPB_a255_valveRelayShort Short between UVR and GND.
- DPB_a256 — Valve Relay Actuation Fault DPB_a256_valveRelayActuationFault Feedback of VRG actuation ot plausible.
- DPB_a257 — Valve Relay On Continuous DPB_a257_valveRelayOnContinuous VR can not be switched off.
- DPB_a258 — Valve Relay Off Continuous DPB_a258_valveRelayOffContinuous VR can not be switched on.
- DPB_a259 — Valve Relay Test Undervoltage DPB_a259_valveRelayTestUndervoltage Conditions for valve relay switch on test not correct.
- DPB_a260 — Valve Relay Safety Switch Fault DPB_a260_valveRelaySafetySwitchFault Redundant safety switch fails.
- DPB_a261 — Wdh Asic Wd Cmd Missing DPB_a261_WdhAsicWdCmdMissing At least one command number for safe backbone monitoring not scheduled from system asic watchdog.
- DPB_a262 — Wdh Asic Wd Error Cnt Limit DPB_a262_WdhAsicWdErrorCntLimit Number of faulty watchdog trigger pattern too high.
- DPB_a263 — Wdh Asic Wd Error Cnt Stuck DPB_a263_WdhAsicWdErrorCntStuck Watchdog of system asic does not react on wrong trigger pattern.
- DPB_a264 — Wdh Sw Bist Con Cnt DPB_a264_WdhSwBistConCnt Dual Core SW-Bist comparison fault.
- DPB_a265 — Wdh Task Mon Con Cnt DPB_a265_WdhTaskMonConCnt Task Monitor reports faulty status.
- DPB_a266 — RPS NvM Read Fault DPB_a266_RPSNvMReadFault Reading of rotor position calibration data from NvM failed.
- DPB_a267 — Rps Angle Implausible DPB_a267_RpsAngleImplausible The alert is logged whenver the absolute deviation between the unfiltered RPS speed and filtered speed exceeds 711.2 rad/s, provided the actuator position is valid.
- DPB_a268 — RPS Vector Oscillating DPB_a268_RPSVectorOscillating rotor position sensor raw signals: vector length is oscillating.
- DPB_a269 — RPS Vector Range High DPB_a269_RPSVectorRangeHigh rotor position sensor raw signals: vector length is too high.
- DPB_a270 — RPS Vector Range Low DPB_a270_RPSVectorRangeLow rotor position sensor raw signals: vector length is too low.
- DPB_a271 — RPS Wrong Calib Data DPB_a271_RPSWrongCalibData Mismatch between RPS calibration data version in NvM and SW version.
- DPB_a272 — Runtime Assertion Fault DPB_a272_runtimeAssertionFault Runtime Assertion Failed.
- DPB_a273 — SMM One Requests Init DPB_a273_SMMOneRequestsInit SMM info alert.
- DPB_a274 — Asw System Time Out DPB_a274_AswSystemTimeOut This alert is not valid anymore.
- DPB_a275 — Ps1 Ps2 Plausibility Fault DPB_a275_Ps1Ps2PlausibilityFault Plausibilization between temperature sensors.
- DPB_a276 — VCFRONT sensors Counter DPB_a276_VCFRONTsensorsCounter This alert is not valid anymore.
- DPB_a277 — VCFRONT sensors Checksum DPB_a277_VCFRONTsensorsChecksum This alert is not valid anymore.
- DPB_a278 — VCFRONT sensors DLC DPB_a278_VCFRONTsensorsDLC This alert is not valid anymore.
- DPB_a279 — VCFRONT sensors Timeout DPB_a279_VCFRONTsensorsTimeout This alert is not valid anymore.
- DPB_a280 — Low Brake Fluid DPB_a280_LowBrakeFluid Brake fluid level low.
- DPB_a281 — Brake Fluid OOR High DPB_a281_brakeFluidOORHigh Brake Fluid Level Out of Range High
- DPB_a282 — DI brake Command Counter DPB_a282_DIbrakeCommandCounter Alive counter error detected.
- DPB_a283 — DI brake Command Checksum DPB_a283_DIbrakeCommandChecksum Checksum error detected.
- DPB_a284 — DI brake Command DLC DPB_a284_DIbrakeCommandDLC error.
- DPB_a285 — DI brake Command Timeout DPB_a285_DIbrakeCommandTimeout Timeout error detected.
- DPB_a286 — Ebr Cmd State Invalid DPB_a286_ebrCmdStateInvalid The External Brake Request (EBR) command state reported by the Pedal Monitor (PM) is invalid.
- DPB_a287 — Brake Cmd State Invalid DPB_a287_brakeCmdStateInvalid error.
- DPB_a288 — Plant Degraded SW DPB_a288_PlantDegradedSW This alert is not valid anymore.
- DPB_a289 — Evac Fill Not Complete DPB_a289_evacFillNotComplete The alert is set to active in the factory plant as long as the function Testerless EvacFill is not successfully executed.
- DPB_a290 — Security Info DPB_a290_securityInfo Lifecycle state is Privileged Mode.
- DPB_a291 — Ext DBR Request Too Low DPB_a291_extDBRRequestTooLow System has detected that the requested external Dynamic Braking Resistor (DBR) falls below the minimum legal required brake torque.
- DPB_a292 — CBDS fill Buffer Threshold DPB_a292_CBDS_fillBufferThreshold Threshold based condition to be used for sending Alert to ODIN to start the data upload sequence.
- DPB_a293 — CBDS fme Internal Event DPB_a293_CBDS_fmeInternalEvent Event based condition to be used for sending Alert to ODIN to start the data upload sequence.
- DPB_a294 — Hba Normal Mode Active DPB_a294_hbaNormalModeActive Hydraulic Brake Assist is active with normal mode.
- DPB_a295 — Hba Track Mode Active DPB_a295_hbaTrackModeActive Hydraulic Brake Assist is active with track mode.
- DPB_a296 — Stat Invalid DI Full SNA DPB_a296_StatInvalid_DI_FullSNA Request with value SNA from DI_brakeTorqueCommandFull has been detected by system.
- DPB_a297 — Undefined Alert Detected DPB_a297_undefinedAlertDetected This alert is set to catch alert memory not mapped by supplier. This alert is also helpful for debugging and troubleshooting in case if ghost degradation is observed.
- DPB_a298 — Running Plunger Circuit Test DPB_a298_runningPlungerCircuitTest Decoupled Power Brake (DPB) is running Plunger Circuit Test.
- DPB_a299 — PM loc State Counter DPB_a299_PM_locStateCounter Alive counter error detected on Pedal Monitoring alive counter signal PM_locStateCounter.
- DPB_a300 — PM loc State Checksum DPB_a300_PM_locStateChecksum Checksum error detected on Pedal Monitoring checksum signal PM_locStateChecksum.