DPB_a275 — Ps1 Ps2 Plausibility Fault
Full alert identifier: DPB_a275_Ps1Ps2PlausibilityFault
Alert description
Plausibilization between temperature sensors.
Potential impact
System will be running with full assistant for driver brake request.
Set condition
temperature sensor defect, alert is set if difference between both temperature sensors exceeds 15 K.
Clear condition
Goodcheck after 60s if difference between temperature sensors is <=12 K.
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a275.