Skip to content

DPB_a268 — RPS Vector Oscillating

Full alert identifier: DPB_a268_RPSVectorOscillating

Alert description

rotor position sensor raw signals: vector length is oscillating.

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

Magnetic field distorted or electrical alert of rotor position sensor raw signals. Oscillations or jumps detected.

Clear condition

Ignition off; wait 5 seconds; Ignition on

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a268.