DPB_a268 — RPS Vector Oscillating
Full alert identifier: DPB_a268_RPSVectorOscillating
Alert description
rotor position sensor raw signals: vector length is oscillating.
Potential impact
System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.
Set condition
Magnetic field distorted or electrical alert of rotor position sensor raw signals. Oscillations or jumps detected.
Clear condition
Ignition off; wait 5 seconds; Ignition on
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a268.