Skip to content

DPB_a237 — U C Voltage Divider Drift

Full alert identifier: DPB_a237_uCVoltageDividerDrift

Alert description

UB_Valve to UBRD_INT plausi voltage divider drift alert (large deviation between UB_Valve to UBRD_INT voltage).

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

Possible voltage divider drift alert (with respect to UB_Valve and UBRD_INT measurement). Voltage difference between UB_Valve and UBRD_INT is checked every specified time. alert is set if preconditions are met (UBRD_INT below active threshold) and the voltage difference exceeds a threshold.

Clear condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a237.

Browse all DPB alert codes