Skip to content

DPB_a051 — PSC Voltage Implausible

Full alert identifier: DPB_a051_PSCVoltageImplausible

Alert description

Based on the motor current vector and speed the voltage vector is not plausible.

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

Based on the differential motor model equations the expected voltage vector is calculated from measured motor phase currents and motor speed. This is compared to the output of the field-oriented current controller. In case of large deviations the alert is triggered.

Clear condition

Ignition off; wait 5 seconds; Ignition on

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a051.

Browse all DPB alert codes