DPB_a225 — U5 V Out Of Range

Full alert identifier: DPB_a225_U5VOutOfRange

Alert description

U5V is out of range.

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

Problem of ASIC reset logic. Monitoring of U5V (internal 5V supply for sensors and communication) out of range bits provided by the ASIC. If U5V is out of range a reset should be issued for the ASIC.

Clear condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a225.