DPB_a218 — Pressure Sensor2 Temp
Full alert identifier: DPB_a218_pressureSensor2Temp
Alert description
Pressure Sensor 2, Temperature Out Of Range.
Potential impact
System will be running with full assistant for driver brake request.
Set condition
(1) Hydraulic Unit and ECU are too hot, Pressure Sensor 2 Temperature is out of range high. (2) Hydraulic Unit and ECU are too cold, Pressure Sensor 2 Temperature is out of range low. (3) Pressure Sensor 2 does not send temperature, Pressure Sensor 2 temperature timeout.
Clear condition
Switch on ECU wait 7 seconds
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a218.