Power conversion system alerts
Browse 203 PCS2 alert codes and open an entry for its description and recorded conditions.
PCS2 alert codes
Showing 51–100 of 203
- PCS2_a051 — Bms Mia PCS2_a051_bmsMia The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the Battery Management System (BMS)
- PCS2_a052 — Cp Mia PCS2_a052_cpMia The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the Charge Port (CP)
- PCS2_a053 — Hv Dcdc Control MIA PCS2_a053_hvDcdcControlMIA The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the High Voltage Processor (HVP)
- PCS2_a054 — Ui Mia PCS2_a054_uiMia The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the User Interface (UI)
- PCS2_a055 — Dcdc A Tank Uncalibrated PCS2_a055_dcdcATankUncalibrated The pack side DCDC converter (DCDCA) resonant tank has not been fully calibrated
- PCS2_a056 — Dcdc B Tank Uncalibrated PCS2_a056_dcdcBTankUncalibrated The DC link side DCDC converter (DCDCB) resonant tank has not been fully calibrated
- PCS2_a057 — Cyclo A Tank Uncalibrated PCS2_a057_cycloATankUncalibrated DCAC converter A (DCACA) resonant tank has not been fully calibrated
- PCS2_a058 — Cyclo B Tank Uncalibrated PCS2_a058_cycloBTankUncalibrated DCAC converter B (DCACB) resonant tank has not been fully calibrated
- PCS2_a059 — Dcdc Enable Line Deasserted PCS2_a059_dcdcEnableLineDeasserted The Power Conversion System (PCS) detects the DCDC ENABLE digital line is deasserted when DCDC is commanded to operate.
- PCS2_a060 — Cyclo A Faulted PCS2_a060_cycloAFaulted DCAC converter A (DCACA) is not operational
- PCS2_a061 — Cyclo B Faulted PCS2_a061_cycloBFaulted DCAC converter B (DCACB) is not operational
- PCS2_a062 — Ac Voltage Not Present PCS2_a062_acVoltageNotPresent AC voltage is not present while the The Power Conversion System (PCS) is expecting AC voltage to be provided by the external charging equipment
- PCS2_a063 — Chg Unknown Grid Config PCS2_a063_chgUnknownGridConfig The Power Conversion System (PCS) detects an unknown grid configuration from the external charging equipment
- PCS2_a064 — Dcdc A Tank Parameters Out Of Spec PCS2_a064_dcdcATankParametersOutOfSpec The pack side DCDC converter (DCDCA) resonant tank calibration data is out of specification
- PCS2_a065 — Dcdc B Tank Parameters Out Of Spec PCS2_a065_dcdcBTankParametersOutOfSpec The DC link side DCDC converter (DCDCB) resonant tank calibration data is out of specification
- PCS2_a066 — Cyclo A Tank Parameters Out Of Spec PCS2_a066_cycloATankParametersOutOfSpec DCAC converter A (DCACA) resonant tank calibration data is out of specification
- PCS2_a067 — Cyclo B Tank Parameters Out Of Spec PCS2_a067_cycloBTankParametersOutOfSpec DCAC converter A (DCACA) resonant tank calibration data is out of specification
- PCS2_a068 — Nvm Subsystem Stalled PCS2_a068_nvmSubsystemStalled Non-Volatile Memory (NVM) record transfer channel stalled
- PCS2_a069 — Dcdc Alifetime Energy Record Faulty PCS2_a069_dcdcAlifetimeEnergyRecordFaulty The pack side DCDC converter (DCDCA) lifetime energy record not ready for use
- PCS2_a070 — Dcdc Blifetime Energy Record Faulty PCS2_a070_dcdcBlifetimeEnergyRecordFaulty The DC link side DCDC converter (DCDCB) lifetime energy record not ready for use
- PCS2_a071 — Hv Batt Bot Sensor Irrational PCS2_a071_hvBattBotSensorIrrational The high voltage (HV) battery bottom voltage measurement is irrational
- PCS2_a072 — Hv Batt Top Sensor Irrational PCS2_a072_hvBattTopSensorIrrational The high voltage (HV) battery top voltage measurement is irrational
- PCS2_a073 — Hv Bus Bot Sensor Irrational PCS2_a073_hvBusBotSensorIrrational The high voltage (HV) bus bottom voltage measurement is irrational
- PCS2_a074 — Hv Bus Top Sensor Irrational PCS2_a074_hvBusTopSensorIrrational The high voltage (HV) bus top voltage measurement is irrational
- PCS2_a075 — Hv Batt Full Sensor Irrational PCS2_a075_hvBattFullSensorIrrational The high voltage (HV) battery full voltage measurement is irrational
- PCS2_a076 — Hv Bus Full Sensor Irrational PCS2_a076_hvBusFullSensorIrrational The high voltage (HV) bus full measurement is irrational
- PCS2_a077 — Lv Bus Volt Sensor Irrational PCS2_a077_lvBusVoltSensorIrrational The low voltage (LV) bus measurement is irrational
- PCS2_a078 — Ac L1 N Voltage Offset Irrational PCS2_a078_acL1NVoltageOffsetIrrational The AC Line 1 to Neutral voltage has an irrationally high DC offset
- PCS2_a079 — Ac L2 N Voltage Offset Irrational PCS2_a079_acL2NVoltageOffsetIrrational The AC Line 2 to Neutral voltage has an irrationally high DC offset
- PCS2_a080 — Ac L3 N Voltage Offset Irrational PCS2_a080_acL3NVoltageOffsetIrrational The AC Line 3 to Neutral voltage has an irrationally high DC offset
- PCS2_a081 — Ac L1 Current Offset Irrational PCS2_a081_acL1CurrentOffsetIrrational The AC Line 1 current has an irrationally high DC offset
- PCS2_a082 — Ac L2 Current Offset Irrational PCS2_a082_acL2CurrentOffsetIrrational The AC Line 2 current has an irrationally high DC offset
- PCS2_a083 — Ac L3 Current Offset Irrational PCS2_a083_acL3CurrentOffsetIrrational The AC Line 3 current has an irrationally high DC offset
- PCS2_a084 — Ac N Current Offset Irrational PCS2_a084_acNCurrentOffsetIrrational The AC Line N current has an irrationally high DC offset
- PCS2_a085 — Dcac Enable Line Deasserted PCS2_a085_dcacEnableLineDeasserted The Power Conversion System (PCS) detects the DCAC ENABLE digital line is deasserted when DCAC is still commanded to operate
- PCS2_a086 — Dcac LV Under Voltage PCS2_a086_dcacLVUnderVoltage The low voltage (LV) bus goes below the allowed voltage threshold
- PCS2_a087 — Dcac LV Over Voltage PCS2_a087_dcacLVOverVoltage The low voltage (LV) bus goes above the allowed voltage threshold
- PCS2_a088 — Chg Input V Drop High PCS2_a088_chgInputVDropHigh During AC charging, the measured root mean squared (RMS) voltage across the lines has decreased below the voltage drop threshold when compared to the RMS voltage at the start of AC charging
- PCS2_a089 — End Of Line Mode Activated PCS2_a089_EndOfLineModeActivated The Power Conversion System (PCS) has been placed into manufacturing EOL (End of Line) mode
- PCS2_a090 — Dcdc Lv Mosfet Temp Too High PCS2_a090_DcdcLvMosfetTempTooHigh The temperature of the thermal model for the DCDC low voltage (LV) metal-oxide-semiconductor field-effect transistors (MOSFETs) becomes too high
- PCS2_a091 — Dcdc Tx Winding Temp Too High PCS2_a091_DcdcTxWindingTempTooHigh The temperature of the thermal model for the DCDC transformer windings becomes too high
- PCS2_a092 — Dcdc itank Zcd Irrational PCS2_a092_dcdc_itankZcdIrrational PCS2's DCDC converter detects resonant tank current zero-crossing event does not occur within the desired time window, this is usually caused by hardware failure
- PCS2_a093 — Cyclo Pwms Not Interleaved PCS2_a093_cycloPwmsNotInterleaved DCAC converter A and DCAC converter B pwm patterns are not interleaved correctly.
- PCS2_a094 — Ac Charging Unavailable PCS2_a094_acChargingUnavailable The Power Conversion System (PCS) detects a condition causing AC charging to be unavailable.
- PCS2_a095 — Powershare Unavailable PCS2_a095_powershareUnavailable The Power Conversion System (PCS) detects a condition causing Powershare to be unavailable.
- PCS2_a096 — Vcsuper Mia PCS2_a096_vcsuperMia The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the Supermanifold Vehicle Controller (VCSUPER)
- PCS2_a097 — Gtw Mia PCS2_a097_gtwMia The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the Vehicle Gateway (GTW)
- PCS2_a098 — Eggright3 Mia PCS2_a098_eggright3Mia The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the Etherloop Generalized Gateway (EGGRIGHT3)
- PCS2_a099 — Line Chassis Rms OV PCS2_a099_LineChassisRmsOV The root mean squared (RMS) voltage from AC Line to Chassis has exceeded the expected RMS voltage threshold
- PCS2_a100 — Line To Line Rms OV PCS2_a100_LineToLineRmsOV The root mean squared (RMS) voltage from AC Line to Line has exceeded the expected RMS voltage threshold