PCS2_a091 — Dcdc Tx Winding Temp Too High

Full alert identifier: PCS2_a091_DcdcTxWindingTempTooHigh

Alert description

The temperature of the thermal model for the DCDC transformer windings becomes too high

Potential impact

The maximum DCDC power may be reduced

Set condition

The temperature of the thermal model for the DCDC transformer windings rises above its set limit

Clear condition

The temperature of the thermal model for the DCDC the transformer windings falls below its clear limit

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Dc Dc Model Tx Winding Coolant Flow Rate PCS2_a091_DcDcModelTxWindingCoolantFlowRate LPM
Dc Dc Model Tx Winding Current PCS2_a091_DcDcModelTxWindingCurrent A
Dcdc Model Tx Winding Coolant Temp PCS2_a091_DcdcModelTxWindingCoolantTemp C
Dcdc Model Tx Winding Temp PCS2_a091_DcdcModelTxWindingTemp C

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a091.

Browse all PCS2 alert codes