PCS2_a058 — Cyclo B Tank Uncalibrated
Full alert identifier: PCS2_a058_cycloBTankUncalibrated
Alert description
DCAC converter B (DCACB) resonant tank has not been fully calibrated
Potential impact
DCAC operation allowed with default resonant tank parameters at reduced surge current limit
Set condition
A tank capacitance or inductance measurement for DCACB is not recorded in Non-Volatile Memory (NVM)
Clear condition
DCACB resonant tank calibration data is within specification
Signals to check
These diagnostic fields are associated with PCS2_a058. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Leakage Inductance Defined
PCS2_
|
— |
Magnetizing Inductance Defined
PCS2_
|
— |
Tank Capacitance Defined
PCS2_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a058.