PCS2_a058 — Cyclo B Tank Uncalibrated

Full alert identifier: PCS2_a058_cycloBTankUncalibrated

Alert description

DCAC converter B (DCACB) resonant tank has not been fully calibrated

Potential impact

DCAC operation allowed with default resonant tank parameters at reduced surge current limit

Set condition

A tank capacitance or inductance measurement for DCACB is not recorded in Non-Volatile Memory (NVM)

Clear condition

DCACB resonant tank calibration data is within specification

Signals to check

These diagnostic fields are associated with PCS2_a058. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Leakage Inductance Defined PCS2_a058_leakageInductanceDefined —
Magnetizing Inductance Defined PCS2_a058_magnetizingInductanceDefined —
Tank Capacitance Defined PCS2_a058_tankCapacitanceDefined —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a058.