Skip to content

PCS2_a014 — Cyclo B Tank Over Current

Full alert identifier: PCS2_a014_cycloBTankOverCurrent

Alert description

The DCAC converter B (DCACB) resonant tank current goes above the allowed current threshold

Potential impact

AC Charging may be limited or unavailable.

Set condition

The DCACB resonant tank current goes above the allowed current threshold

Clear condition

The DCAC system retries

Signals to check

These diagnostic fields are associated with PCS2_a014. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Cyclo B Tank Over Current Trip PCS2_a014_cycloBTankOverCurrentTrip
0
COMPH TRIP
1
COMPL TRIP
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a014.

Browse all PCS2 alert codes