Skip to content

PCS2_a095 — Powershare Unavailable

Full alert identifier: PCS2_a095_powershareUnavailable

Message shown in the car

Powershare unavailable Schedule service

Alert description

The Power Conversion System (PCS) detects a condition causing Powershare to be unavailable.

Potential impact

AC Charging may be limited or unavailable.

Set condition

PCS detects a condition causing Powershare to be unavailable. See alert log signal data for more information.

Clear condition

PCS no longer detects the condition affecting Powershare functionality.

Signals to check

These diagnostic fields are associated with PCS2_a095. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Cyclo A Blocked Reason PCS2_a095_cycloABlockedReason
0
NOT BLOCKED
1
BLOCKED DUE TO OVER TEMP
2
BLOCKED DUE TO HVDC OVER CURRENT
3
BLOCKED DUE TO HEALTH CHECK FAILED
4
BLOCKED DUE TO AUX RAIL PERMANENT FAULT
5
NUM BLOCKED REASONS
—
Cyclo B Blocked Reason PCS2_a095_cycloBBlockedReason
0
NOT BLOCKED
1
BLOCKED DUE TO OVER TEMP
2
BLOCKED DUE TO HVDC OVER CURRENT
3
BLOCKED DUE TO HEALTH CHECK FAILED
4
BLOCKED DUE TO AUX RAIL PERMANENT FAULT
5
NUM BLOCKED REASONS
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a095.

Browse all PCS2 alert codes