Skip to content

PCS2_a075 — Hv Batt Full Sensor Irrational

Full alert identifier: PCS2_a075_hvBattFullSensorIrrational

Alert description

The high voltage (HV) battery full voltage measurement is irrational

Potential impact

DCDC and AC Charging may be limited or unavailable.

Set condition

The HV battery full voltage is irrationally high or low

Clear condition

The HV battery full voltage measurement comes back within a rational sensor range

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Hv Batt External Ref Value PCS2_a075_hvBattExternalRefValue
2047
SNA
V
Hv Batt Full Sensor Measurement PCS2_a075_hvBattFullSensorMeasurement V
Hv Batt Top Bottom Voltage Delta PCS2_a075_hvBattTopBottomVoltageDelta V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a075.

Browse all PCS2 alert codes