Skip to content

PCS2_a073 — Hv Bus Bot Sensor Irrational

Full alert identifier: PCS2_a073_hvBusBotSensorIrrational

Alert description

The high voltage (HV) bus bottom voltage measurement is irrational

Potential impact

DCDC and AC Charging may be limited or unavailable.

Set condition

The HV bus bottom voltage is irrationally high or low

Clear condition

The HV bus bottom voltage measurement comes back within a rational sensor range

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Hv Bus Bot Sensor Measurement PCS2_a073_hvBusBotSensorMeasurement V
Hv Bus External Ref Value PCS2_a073_hvBusExternalRefValue
2047
SNA
V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a073.

Browse all PCS2 alert codes