PCS2_a052 — Cp Mia
Full alert identifier: PCS2_a052_cpMia
Alert description
The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the Charge Port (CP)
Potential impact
AC Charging may be limited or unavailable.
Set condition
The PCS does not receive all expected CAN messages from the CP
Clear condition
The PCS receives all expected CAN messages from the CP
Signals to check
These diagnostic fields are associated with PCS2_a052. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
CP Charge Status
PCS2_
|
— |
CP Epto Status
PCS2_
|
— |
CP Grid Form Control
PCS2_
|
— |
CP Status
PCS2_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a052.