Power conversion system alerts
Browse 203 PCS2 alert codes and open an entry for its description and recorded conditions.
PCS2 alert codes
Showing 1–50 of 203
- PCS2_a001 — Watchdog Alarmed PCS2_a001_watchdogAlarmed System experienced a watchdog reset
- PCS2_a002 — Can Rationality PCS2_a002_canRationality The Power Conversion System (PCS) controller area network (CAN) receiver encounters an error while receiving messages.
- PCS2_a003 — Software Assertion PCS2_a003_softwareAssertion An unexpected software behavior is detected
- PCS2_a004 — Ac L1 N Over Voltage PCS2_a004_acL1NOverVoltage The AC Line 1 to Neutral voltage exceeds the allowed voltage threshold
- PCS2_a005 — Ac L1 Over Current PCS2_a005_acL1OverCurrent The AC Line 1 current exceeds the allowed current threshold
- PCS2_a006 — Ac L2 N Over Voltage PCS2_a006_acL2NOverVoltage The AC Line 2 to Neutral voltage exceeds the allowed voltage threshold
- PCS2_a007 — Ac L2 Over Current PCS2_a007_acL2OverCurrent The AC Line 2 current exceeds the allowed current threshold
- PCS2_a008 — Ac L3 N Over Voltage PCS2_a008_acL3NOverVoltage The AC Line 2 to Neutral voltage exceeds the allowed voltage threshold
- PCS2_a009 — Ac L3 Over Current PCS2_a009_acL3OverCurrent The AC Line 3 current exceeds the allowed current threshold
- PCS2_a010 — Ac LN Over Current PCS2_a010_acLNOverCurrent The AC Neutral current exceeds the allowed current threshold
- PCS2_a011 — Hvdc Over Current PCS2_a011_hvdcOverCurrent The high voltage (HV) DC current goes above the allowed current threshold
- PCS2_a012 — Cyclo A Tank Over Current PCS2_a012_cycloATankOverCurrent The DCAC converter A (DCACA) resonant tank current goes above the allowed current threshold
- PCS2_a013 — Dcdc A Lv2 Over Temp PCS2_a013_DcdcALv2OverTemp The low voltage (LV) side of the pack side DCDC converter (DCDCA) temperature is too high
- PCS2_a014 — Cyclo B Tank Over Current PCS2_a014_cycloBTankOverCurrent The DCAC converter B (DCACB) resonant tank current goes above the allowed current threshold
- PCS2_a015 — Dcdc A Hv Over Temp PCS2_a015_DcdcAHvOverTemp The high voltage (HV) side of the pack side DCDC converter (DCDCA) temperature is too high
- PCS2_a016 — Dcdc A Tank Over Current PCS2_a016_dcdcATankOverCurrent The pack side DCDC converter (DCDCA) resonant tank current goes above the allowed current threshold
- PCS2_a017 — Dcdc B Lv2 Over Temp PCS2_a017_DcdcBLv2OverTemp The low voltage (LV) side of the DC link DCDC converter (DCDCB) temperature is too high
- PCS2_a018 — Dcdc B Tank Over Current PCS2_a018_dcdcBTankOverCurrent The DC link side DCDC converter (DCDCB) resonant tank current goes above the allowed current threshold
- PCS2_a019 — Dcac A Dc Temp Too High PCS2_a019_DcacADcTempTooHigh DC side of DCAC converter A (DCACA) temperature is too high
- PCS2_a020 — Dcac B Dc Temp Too High PCS2_a020_DcacBDcTempTooHigh DC side of DCAC converter B (DCACB) temperature is too high
- PCS2_a021 — Power Rail Under Voltage PCS2_a021_powerRailUnderVoltage The generated power rail (4.5V, 10V, 13.5V, 18V, or 48V) has gone lower than the allowed lower threshold
- PCS2_a022 — Dcac Enable Functionality Disabled PCS2_a022_dcacEnableFunctionalityDisabled The DCAC ENABLE hard line functionality is disabled
- PCS2_a023 — Dcdc Enable Functionality Disabled PCS2_a023_dcdcEnableFunctionalityDisabled The DCDC ENABLE hard line functionality is disabled
- PCS2_a024 — Dcac A Tx Temp Too High PCS2_a024_DcacATxTempTooHigh The planar transformer of DCAC converter A (DCACA) temperature is too high
- PCS2_a025 — Dcac B Tx Temp Too High PCS2_a025_DcacBTxTempTooHigh The planar transformer of DCAC converter B (DCACB) temperature is too high
- PCS2_a026 — Ac Connector Temp Too High PCS2_a026_AcConnectorTempTooHigh The AC connector temperature is too high
- PCS2_a027 — Ambient Temp Too High PCS2_a027_AmbientTempTooHigh The Power Convertsion System (PCS) ambient temperature is too high
- PCS2_a028 — Coolant Temp Too High PCS2_a028_CoolantTempTooHigh The coolant temperature is too high
- PCS2_a029 — Dcac A Ac1 Temp Too High PCS2_a029_DcacAAc1TempTooHigh DCAC converter A (DCACA) AC side sensor 1 (AC1) temperature is too high
- PCS2_a030 — Dcac A Ac2 Temp Too High PCS2_a030_DcacAAc2TempTooHigh DCAC converter A (DCACA) AC side sensor 2 (AC2) temperature is too high
- PCS2_a031 — Dcac B Ac1 Temp Too High PCS2_a031_DcacBAc1TempTooHigh DCAC converter B (DCACB) AC side sensor 1 (AC1) temperature is too high
- PCS2_a032 — Dcac B Ac2 Temp Too High PCS2_a032_DcacBAc2TempTooHigh DCAC converter B (DCACB) AC side sensor 2 (AC2) temperature is too high
- PCS2_a033 — Sw Core Excessive Usage PCS2_a033_swCoreExcessiveUsage A real time operating system (RTOS) software task is overloaded and has exceeded its utilization threshold
- PCS2_a034 — Lv Bus Over Voltage PCS2_a034_lvBusOverVoltage The low voltage (LV) bus goes above the allowed voltage threshold
- PCS2_a035 — Lv Bus Under Voltage PCS2_a035_lvBusUnderVoltage The low voltage (LV) bus goes below the allowed voltage threshold
- PCS2_a036 — Hv Bus Over Voltage PCS2_a036_hvBusOverVoltage The high voltage (HV) bus goes above the allowed voltage threshold
- PCS2_a037 — Hv Bus Under Voltage PCS2_a037_hvBusUnderVoltage The high voltage (HV) bus goes below the allowed voltage threshold
- PCS2_a038 — Hv Bus Top Over Voltage PCS2_a038_hvBusTopOverVoltage The sensor measuring the top half of the high voltage (HV) bus voltage detects a value above the allowed voltage threshold
- PCS2_a039 — Hv Bus Top Under Voltage PCS2_a039_hvBusTopUnderVoltage The sensor measuring the top half of the high voltage (HV) bus voltage detects a value below the allowed voltage threshold
- PCS2_a040 — Hv Bus Bot Over Voltage PCS2_a040_hvBusBotOverVoltage The sensor measuring the bottom half of the high voltage (HV) bus voltage detects a value above the allowed voltage threshold
- PCS2_a041 — Hv Bus Bot Under Voltage PCS2_a041_hvBusBotUnderVoltage The sensor measuring the bottom half of the high voltage (HV) bus voltage detects a value below the allowed voltage threshold
- PCS2_a042 — Hv Batt Over Voltage PCS2_a042_hvBattOverVoltage The high voltage (HV) battery goes above the allowed voltage threshold
- PCS2_a043 — Hv Batt Under Voltage PCS2_a043_hvBattUnderVoltage The high voltage (HV) battery goes below the allowed voltage threshold
- PCS2_a044 — Hv Batt Top Over Voltage PCS2_a044_hvBattTopOverVoltage The sensor measuring the top half of the high voltage (HV) battery voltage detects a value above the allowed voltage threshold
- PCS2_a045 — Hv Batt Top Under Voltage PCS2_a045_hvBattTopUnderVoltage The sensor measuring the top half of the high voltage (HV) battery voltage detects a value below the allowed voltage threshold
- PCS2_a046 — Hv Batt Bot Over Voltage PCS2_a046_hvBattBotOverVoltage The sensor measuring the bottom half of the high voltage (HV) battery voltage detects a value above the allowed voltage threshold
- PCS2_a047 — Hv Batt Bot Under Voltage PCS2_a047_hvBattBotUnderVoltage The sensor measuring the bottom half of the high voltage (HV) battery voltage detects a value below the allowed voltage threshold
- PCS2_a048 — Dcac Over Voltage PCS2_a048_dcacOverVoltage The DCAC high voltage (HV) measurement goes above the allowed voltage threshold
- PCS2_a049 — Dcac Under Voltage PCS2_a049_dcacUnderVoltage The DCAC high voltage (HV) measurement goes below the allowed voltage threshold
- PCS2_a050 — Vc Pcs DCDC Interface Mia PCS2_a050_vcPcsDCDCInterfaceMia The Power Conversion System (PCS) does not receive one or more DCDC interface Controller Area Network (CAN) messages from the Vehicle Controller (VC)