PCS2_a038 — Hv Bus Top Over Voltage

Full alert identifier: PCS2_a038_hvBusTopOverVoltage

Alert description

The sensor measuring the top half of the high voltage (HV) bus voltage detects a value above the allowed voltage threshold

Potential impact

DCDC functionality may be limited or paused

Set condition

The sensor measuring the top half of the HV bus voltage goes above the allowed voltage threshold

Clear condition

The DCDC system retries

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Hv Bus Bot Voltage PCS2_a038_hvBusBotVoltage V
Hv Bus Top Voltage PCS2_a038_hvBusTopVoltage V
Hv Bus Voltage PCS2_a038_hvBusVoltage V
Voltage Fault Threshold PCS2_a038_voltageFaultThreshold V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a038.

Browse all PCS2 alert codes