Skip to content

PCS2_a053 — Hv Dcdc Control MIA

Full alert identifier: PCS2_a053_hvDcdcControlMIA

Alert description

The Power Conversion System (PCS) does not receive one or more Controller Area Network (CAN) messages from the High Voltage Processor (HVP)

Potential impact

AC Charging may be limited or unavailable.

Set condition

The PCS does not receive all expected CAN messages from high voltage processor

Clear condition

The PCS receives all expected CAN messages from high voltage processor

Signals to check

These diagnostic fields are associated with PCS2_a053. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
HVP Hvs Control PCS2_a053_HVP_hvsControl —
HV Dcdc Control PCS2_a053_HV_dcdcControl —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a053.

Browse all PCS2 alert codes