Skip to content

PCS2_a067 — Cyclo B Tank Parameters Out Of Spec

Full alert identifier: PCS2_a067_cycloBTankParametersOutOfSpec

Alert description

DCAC converter A (DCACA) resonant tank calibration data is out of specification

Potential impact

DCAC operation allowed with default resonant tank parameters at reduced surge current limit

Set condition

A tank capacitance or inductance measurement for DCACA is not withinthe design margin

Clear condition

DCACA resonant tank calibration data is within specification

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Capacitance PCS2_a067_capacitance nF
Leakage Inductance PCS2_a067_leakageInductance uH
Magnetizing Inductance PCS2_a067_magnetizingInductance uH
Signal Unit
Capacitance Out Of Spec PCS2_a067_capacitanceOutOfSpec —
Leakage Inductance Out Of Spec PCS2_a067_leakageInductanceOutOfSpec —
Magnetizing Inductance Out Of Spec PCS2_a067_magnetizingInductanceOutOfSpec —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS2_a067.

Browse all PCS2 alert codes