Decoupled power brake alerts
Browse 337 DPB alert codes and open an entry for its description and recorded conditions.
DPB alert codes
Showing 51–100 of 337
- DPB_a051 — PSC Voltage Implausible DPB_a051_PSCVoltageImplausible Based on the motor current vector and speed the voltage vector is not plausible.
- DPB_a052 — PSID Time Out DPB_a052_PSIDTimeOut Pressure sensor Time Out after 4 Seconds.
- DPB_a053 — Hydraulic Assembly Mode Active DPB_a053_hydraulicAssemblyModeActive Hydraulic module is in assembly mode.
- DPB_a054 — Unsupported HW DPB_a054_unsupportedHW The software flashed to the Decoupled Power Brake (DPB) is not supported.
- DPB_a055 — Unsupported Series HW Detected DPB_a055_unsupportedSeriesHWDetected Detected hardware is not allowed in a production level ECU.
- DPB_a056 — Adc Peripheral Fault DPB_a056_AdcPeripheralFault A condition affecting the Analog-to-Digital Converter (ADC) is detected.
- DPB_a057 — Adc Pin Test DPB_a057_AdcPinTest An Analog-to-Digital Converter (ADC) pin test reports one of the ADC pins are open.
- DPB_a058 — Adc Selftest C5 P DPB_a058_AdcSelftestC5P ADC Selftest C5P detects unexpected results.
- DPB_a059 — Factory Mode Active DPB_a059_factoryModeActive The Decoupled Power Brake (DPB) is in factory mode.
- DPB_a060 — Motor Bridge Driver Fault DPB_a060_motorBridgeDriverFault The Decoupled Power Brake (EPB) ECU encountered a non-serviceable internal condition.
- DPB_a061 — Bridge Switch Init Error DPB_a061_bridgeSwitchInitError There is a non-serviceable internal condition affecting the Decoupled Power Brake (DPB) ECU bridge driver supply switch MOSFET.
- DPB_a062 — Load Dump On FSL Test DPB_a062_loadDumpOnFSLTest Load Dump Event Before or During Fail Safe Logic Test.
- DPB_a063 — Motor Config Mismatch DPB_a063_motorConfigMismatch Incorrect motor configuration is read from the Non-Volatile Memory (NVM).
- DPB_a064 — Current1 Offset High DPB_a064_current1OffsetHigh The offset of current 1 is higher than expected.
- DPB_a065 — Current1 Offset Low DPB_a065_current1OffsetLow The offset of current 1 is lower than expected.
- DPB_a066 — Current2 Offset High DPB_a066_current2OffsetHigh The offset of current 2 is higher than expected.
- DPB_a067 — Current2 Offset Low DPB_a067_current2OffsetLow The offset of current 2 is lower than expected.
- DPB_a068 — BLM Muxer Timeout Error DPB_a068_BLMMuxerTimeoutError Brushless Motor Muxer Timeout Error.
- DPB_a069 — OBD Current1 OOR High DPB_a069_OBDCurrent1OORHigh Phase 1 current is higher than expected.
- DPB_a070 — OBD Current1 OOR Low DPB_a070_OBDCurrent1OORLow Phase 1 current is lower than expected.
- DPB_a071 — OBD Current2 OOR High DPB_a071_OBDCurrent2OORHigh Phase 2 current is higher than expected.
- DPB_a072 — OBD Current2 OOR Low DPB_a072_OBDCurrent2OORLow Phase 2 current is lower than expected.
- DPB_a073 — Rotor Cos Out Of Range High DPB_a073_rotorCosOutOfRangeHigh The rotation position sensor reports a higher Cos+ or Cos- value than expected.
- DPB_a074 — Rotor Cos Out Of Range Low DPB_a074_rotorCosOutOfRangeLow The rotation position sensor reports a lower Cos+ or Cos- value than expected.
- DPB_a075 — Rotor Sin Out Of Range High DPB_a075_rotorSinOutOfRangeHigh The rotation position sensor reports a higher Sin+ or Sin- value than expected.
- DPB_a076 — Rotor Sin Out Of Range Low DPB_a076_rotorSinOutOfRangeLow The rotation position sensor reports a lower Sin+ or Sin- value than expected.
- DPB_a077 — Temp Sens1 Short To Supply DPB_a077_tempSens1ShortToSupply The Brushless Motor (BLM) is shorted to supply voltage.
- DPB_a078 — Temp Sens1 Short To Ground DPB_a078_tempSens1ShortToGround The Brushless Motor (BLM) is shorted to ground.
- DPB_a079 — Temp Sens2 Short To Supply DPB_a079_tempSens2ShortToSupply The Brushless Motor (BLM) is shorted to supply voltage.
- DPB_a080 — Temp Sens2 Short To Ground DPB_a080_tempSens2ShortToGround The Brushless Motor (BLM) is shorted to ground.
- DPB_a081 — Temp Sens Implaus Voltage DPB_a081_tempSensImplausVoltage The Brushless Motor (BLM) temperature sensors report implausible values.
- DPB_a082 — Charge Pump Fault DPB_a082_chargePumpFault The charge pump is not operating as expected.
- DPB_a083 — Charge Pump Undervoltage DPB_a083_chargePumpUndervoltage The charge pump is undervoltage.
- DPB_a084 — RBCPU Exception DPB_a084_RBCPUException CPU exception occurred.
- DPB_a085 — Info Failure Wrong CUBAS Handling Detected DPB_a085_infoFailureWrongCUBASHandlingDetected Diagnostic Application Callback Handler information alert for indication of wrong callback handling of stack.
- DPB_a086 — Diag Hyd Protection Press Fault DPB_a086_diagHydProtectionPressFault High system pressure protection is enabled.
- DPB_a087 — Diag Hyd Protection Vlv Fault DPB_a087_diagHydProtectionVlvFault Valve overheat protection is enabled.
- DPB_a088 — DMA Transfer Error DPB_a088_DMATransferError Transfer error occurred during a Direct Memory Access (DMA) transfer.
- DPB_a089 — Ecu Bandgap DPB_a089_ecuBandgap The Decoupled Power Brake (DPB) ECU reports a condition affecting its bandgap.
- DPB_a090 — Flash Fault DPB_a090_flashFault The Decoupled Power Brake (DPB) reports an issue during flashing.
- DPB_a091 — MRG Path Test Fault DPB_a091_MRGPathTestFault The control over MRG via EN_HY or MRAUC or both does not work.
- DPB_a092 — Decouple Bit Test Fault DPB_a092_decoupleBitTestFault Alert in system ASIC: Electric or hyraulic decouple bit not reset automatically.
- DPB_a093 — Ecu Bist Fault Ctr Fault DPB_a093_ecuBistFaultCtrFault Built-In Self Test (BIST) didn't switch off electrically after too much received wrong BIST commands.
- DPB_a094 — Ecu Clock Test Fault DPB_a094_ecuClockTestFault Clockin monitor of system IC reports wrong clockin alert status to uC.
- DPB_a095 — Ecu Enable El High Fault DPB_a095_ecuEnableElHighFault The electric enable can't be switched on via the uC port and via the system IC.
- DPB_a096 — Ecu Enable El Low Fault DPB_a096_ecuEnableElLowFault The electric enable can't be switched off via the uC port and via the system IC.
- DPB_a097 — Ecu Enable Hy High Fault DPB_a097_ecuEnableHyHighFault The hydraulic enable line can't be switched on via the uC and via the system IC.
- DPB_a098 — Ecu Enable Hy Low Fault DPB_a098_ecuEnableHyLowFault The hydraulic enable line can't be switched off via the uC or via the system IC.
- DPB_a099 — Ecu En Continuous Error DPB_a099_ecuEnContinuousError Continuous monitor of enable lines detected a missing(low) enable signal.
- DPB_a100 — Ecu Errpin Counter Fault DPB_a100_ecuErrpinCounterFault Alert in system ASIC: Errorpin event not counted.