Skip to content

DPB_a094 — Ecu Clock Test Fault

Full alert identifier: DPB_a094_ecuClockTestFault

Alert description

Clockin monitor of system IC reports wrong clockin alert status to uC.

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

Erroneous safety logic (The clockin monitor of the system IC reports wrong clockin alert status to the uC). This alert is logged if the feedback to the uC does not show the expected clockin alert state.

Clear condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a094.

Browse all DPB alert codes