Skip to content

DPB_a106 — Ecu Bist Cmd Test Fault

Full alert identifier: DPB_a106_ecuBistCmdTestFault

Alert description

Contrary to spec Built-In Self Test (BIST) state machine of system IC is started by a wrong BIST command.

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

Erroneous safety logic (the BIST state machine of the system chip could be activated by a wrong BIST command value), The failsafe logic test tests whether the BIST state machine does detect and suppress a wrong BIST command value. This alert is logged if the watchdog of the system chip is triggered by the wrong BIST command value.

Clear condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a106.

Browse all DPB alert codes