DPB_a099 — Ecu En Continuous Error

Full alert identifier: DPB_a099_ecuEnContinuousError

Alert description

Continuous monitor of enable lines detected a missing(low) enable signal.

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

Interruption or short to GND of a monitored ECU internal enable line. After the failsafe logic test has finished the ECU internal enable lines are monitored. It is expected that the enable lines always stay at high level (except the SW intends another state). If this is not the case this fault is logged.

Clear condition

No internal issue is detected after changing operation cycle. If the condition persists, the DPB module may require replacement.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a099.