Skip to content

DPB_a083 — Charge Pump Undervoltage

Full alert identifier: DPB_a083_chargePumpUndervoltage

Alert description

The charge pump is undervoltage.

Potential impact

System will be running in fully degraded state. Braking may require increased effort. Hydraulic Boost Compensation will be triggered when driver pressed brake pedal.

Set condition

The voltage at the charge pump is less than expected.

Clear condition

System continues to execute charge pump tests every 19s and will good check if execution is successful.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DPB_a083.