Skip to content

HVP_w050 — Fc Ctr Close Failed

Full alert identifier: HVP_w050_fcCtrCloseFailed

Alert description

The Fast Charge (FC) contactor is unable to close. This results in the inability to Fast Charge.

Potential impact

The vehicle is unable to fast charge, but AC charging is not impacted.

Set condition

The FC contactor is unable to close.

Clear condition

The FC contactor is successfully closed.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Coil Current HVP_a050_coilCurrent A
Contactor Power V HVP_a050_contactorPowerV V
Signal Unit
Neg Ctr State HVP_a050_negCtrState
0
SNA
1
OPEN
2
PRECHARGE
3
BLOCKED
4
PULLED IN
5
OPENING
6
ECONOMIZED
7
WELDED
—
Pos Ctr State HVP_a050_posCtrState
0
SNA
1
OPEN
2
PRECHARGE
3
BLOCKED
4
PULLED IN
5
OPENING
6
ECONOMIZED
7
WELDED
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w050.

Browse all HVP alert codes