HVP_w042 — Fc Ctr Close Blocked
Full alert identifier: HVP_w042_fcCtrCloseBlocked
Alert description
The High Voltage Processor (HVP) is blocking the Fast Charge (FC) contactors from closing.
Potential impact
The FC contactors are unable to close. The vehicle will not be able to DC charge.
Set condition
The HVP is blocking the FC contactors from closing. Confirm specific set condition using alert log signal data.
Clear condition
The condition causing the HVP to block the FC contactors from closing is cleared.
Signals to check
These diagnostic fields are associated with HVP_w042. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Bms Hvs Mia
HVP_
|
— |
Contactor State Welded
HVP_
|
— |
Cp Fault
HVP_
|
— |
Cp Mia
HVP_
|
— |
Cp Version Mismatch
HVP_
|
— |
Crash Event
HVP_
|
— |
Fc Contactor Hw
HVP_
|
— |
Hvil Fault
HVP_
|
— |
Show 14 more fields
| Signal | Unit |
|---|---|
Not Allowedto Energize
HVP_
|
— |
Over Charge Current
HVP_
|
— |
Over Current
HVP_
|
— |
Over Discharge Current
HVP_
|
— |
Over Temperature
HVP_
|
— |
Over Voltage
HVP_
|
— |
Pack Contactor Closing
HVP_
|
— |
Pack Contactor Opening
HVP_
|
— |
Pack Voltage Mismatch
HVP_
|
— |
Reset Request Required
HVP_
|
— |
Shunt Current Mia
HVP_
|
— |
Shunt Hw Mia
HVP_
|
— |
Supply 12 V
HVP_
|
— |
Supply Ver
HVP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w042.