Full alert identifier: HVP_w042_fcCtrCloseBlocked

Alert description

The High Voltage Processor (HVP) is blocking the Fast Charge (FC) contactors from closing.

Potential impact

The FC contactors are unable to close. The vehicle will not be able to DC charge.

Set condition

The HVP is blocking the FC contactors from closing. Confirm specific set condition using alert log signal data.

Clear condition

The condition causing the HVP to block the FC contactors from closing is cleared.

Signals to check

These diagnostic fields are associated with HVP_w042. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Bms Hvs Mia HVP_a042_bmsHvsMia —
Contactor State Welded HVP_a042_contactorStateWelded —
Cp Fault HVP_a042_cpFault —
Cp Mia HVP_a042_cpMia —
Cp Version Mismatch HVP_a042_cpVersionMismatch —
Crash Event HVP_a042_crashEvent —
Fc Contactor Hw HVP_a042_fcContactorHw —
Hvil Fault HVP_a042_hvilFault —
Show 14 more fields
Signal Unit
Not Allowedto Energize HVP_a042_notAllowedtoEnergize —
Over Charge Current HVP_a042_overChargeCurrent —
Over Current HVP_a042_overCurrent —
Over Discharge Current HVP_a042_overDischargeCurrent —
Over Temperature HVP_a042_overTemperature —
Over Voltage HVP_a042_overVoltage —
Pack Contactor Closing HVP_a042_packContactorClosing —
Pack Contactor Opening HVP_a042_packContactorOpening —
Pack Voltage Mismatch HVP_a042_packVoltageMismatch —
Reset Request Required HVP_a042_resetRequestRequired —
Shunt Current Mia HVP_a042_shuntCurrentMia —
Shunt Hw Mia HVP_a042_shuntHwMia —
Supply 12 V HVP_a042_supply12V —
Supply Ver HVP_a042_supplyVer —