HVP_w049 — Pack Ctr Close Failed
Full alert identifier: HVP_w049_packCtrCloseFailed
Alert description
The High Voltage Processor (HVP) has detected a pack contactor has entered blocked state.
Potential impact
The pack contactors did not close. The High Voltage System may not function as expected.
Set condition
The HVP has detected a pack contactor has entered blocked state. The HVP may have timed out trying to close the pack contactor.
Clear condition
The pack contactor leaves blocked state.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Coil Current
HVP_
|
A |
Contactor Power V
HVP_
|
V |
| Signal | Unit |
|---|---|
Neg Ctr State
HVP_
|
— |
Pos Ctr State
HVP_
|
— |
Check other alerts