HVP_w041 — Pack Ctr Close Blocked
Full alert identifier: HVP_w041_packCtrCloseBlocked
Alert description
Warn if pack contactors are not allowed to close
Potential impact
While this alert is set, HV contactors will not be able to close. This will prevent drive, charge and 12V support and eventually the 12V battery will be fully discharged and the vehicle will go offline.
Set condition
This meta alert will set if any of the reasons for preventing contactors to close (listed in this alert payload) are still present. This alert is always set with an accompanying alert that provides more specific information for the fault.
Clear condition
Pack contactor blocking condition is cleared
Signals to check
These diagnostic fields are associated with HVP_w041. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Bmb Mia
HVP_
|
— |
Contactor State Welded
HVP_
|
— |
Crash Event
HVP_
|
— |
Dc Link Over Voltage
HVP_
|
— |
Fc Contactor Closing
HVP_
|
— |
Fc Contactor Opening
HVP_
|
— |
Gpo Request Active
HVP_
|
— |
Hvil Fault
HVP_
|
— |
Show 13 more fields
| Signal | Unit |
|---|---|
Not Allowedto Energize
HVP_
|
— |
Over Charge Current
HVP_
|
— |
Over Current
HVP_
|
— |
Over Discharge Current
HVP_
|
— |
Over Temperature
HVP_
|
— |
Over Voltage
HVP_
|
— |
Pack Contactor Hw
HVP_
|
— |
Pack Voltage Mismatch
HVP_
|
— |
Pyro Fault
HVP_
|
— |
Reset Request Required
HVP_
|
— |
Shunt Current Mia
HVP_
|
— |
Shunt Hw Mia
HVP_
|
— |
Under Voltage
HVP_
|
— |
Check other alerts