HVP_w044 — Fc Contactor Force Open

Full alert identifier: HVP_w044_fcContactorForceOpen

Alert description

The High Voltage Processor (HVP) has forced the Fast Charge (FC) contactors open despite the FC contactor state being closed.

Potential impact

The HVP opened the FC contactors. The vehicle may not be able to Supercharge or DC charge.

Set condition

The HVP has forced the FC contactors open despite the FC contactor state being closed. Confirm specific set condition using alert log signal data.

Clear condition

The HVP detects the FC contactor state as open.

Signals to check

These diagnostic fields are associated with HVP_w044. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Bms Hvs Mia HVP_a044_bmsHvsMia —
Contactor Opened HVP_a044_contactorOpened —
Cp Fault HVP_a044_cpFault —
Cp Mia HVP_a044_cpMia —
Cp Version Mismatch HVP_a044_cpVersionMismatch —
Crash Event HVP_a044_crashEvent —
Fc Contactor Hw HVP_a044_fcContactorHw —
Not Allowedto Energize HVP_a044_notAllowedtoEnergize —
Show 8 more fields
Signal Unit
Over Charge Current HVP_a044_overChargeCurrent —
Over Current HVP_a044_overCurrent —
Over Discharge Current HVP_a044_overDischargeCurrent —
Over Temperature HVP_a044_overTemperature —
Over Voltage HVP_a044_overVoltage —
Pack Voltage Mismatch HVP_a044_packVoltageMismatch —
Supply 12 V HVP_a044_supply12V —
Supply Ver HVP_a044_supplyVer —