HVP_w039 — Pack Contactor Fell Open

Full alert identifier: HVP_w039_PackContactorFellOpen

Alert description

The High Voltage Processor (HVP) has detected a pack contactor has opened during a closed state.

Potential impact

The pack contactor state will appear as open. The vehicle powertrain may unexpectedly lose high voltage power under load.

Set condition

The HVP has detected a voltage drop across the contactor and low contactor coil current, indicating a pack contactor has opened despite being in a closed state.

Clear condition

The HVP detects the pack contactor state as open.

Signals to check

These diagnostic fields are associated with HVP_w039. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Neg Contactor Failed HVP_a039_negContactorFailed —
Pos Contactor Failed HVP_a039_posContactorFailed —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w039.

Browse all HVP alert codes