HVP_w043 — Pack Contactor Force Open

Full alert identifier: HVP_w043_packContactorForceOpen

Alert description

The High Voltage Processor (HVP) has forced the pack contactors open despite the pack contactor state being closed.

Potential impact

The HVP opened the pack contactors. High voltage will be isolated to just the battery.

Set condition

The HVP has forced the pack contactors open despite the pack contactor state being closed. Confirm specific set condition using alert log signal data.

Clear condition

The HVP detects the pack contactor state as open.

Signals to check

These diagnostic fields are associated with HVP_w043. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Bmb Mia HVP_a043_bmbMia —
Contactor Opened HVP_a043_contactorOpened —
Crash Event HVP_a043_crashEvent —
Not Allowedto Energize HVP_a043_notAllowedtoEnergize —
Over Charge Current HVP_a043_overChargeCurrent —
Over Current HVP_a043_overCurrent —
Over Discharge Current HVP_a043_overDischargeCurrent —
Over Temperature HVP_a043_overTemperature —
Show 3 more fields
Signal Unit
Over Voltage HVP_a043_overVoltage —
Pack Contactor Hw HVP_a043_packContactorHw —
Under Voltage HVP_a043_underVoltage —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w043.