HVP_w056 — Contactor Failed To Open
Full alert identifier: HVP_w056_contactorFailedToOpen
Alert description
One or more fast charge (FC) or pack contactors in the high voltage battery failed to open when requested
Potential impact
Pyro fuse will blow, which will cut off all high voltage (including charging)
Set condition
The contactor(s) do not open when requested to open immediately
Clear condition
High Voltage Processor (HVP) reset
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Shunt Current
HVP_
|
A |
| Signal | Unit |
|---|---|
Diagnosis
HVP_
|
— |
Neg Fc Contactor State
HVP_
|
— |
Neg Pack Contactor State
HVP_
|
— |
Pos Fc Contactor State
HVP_
|
— |
Pos Pack Contactor State
HVP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w056.