HVP_w040 — Fc Contactor Fell Open
Full alert identifier: HVP_w040_FcContactorFellOpen
Alert description
The High Voltage Processor (HVP) has detected a Fast Charge (FC) contactor has opened during a closed state.
Potential impact
The FC contactors will open. The vehicle may not be able to DC charge. The current charging session may be unexpectedly terminated as the FC contactors open.
Set condition
The HVP has detected a voltage drop across the FC contactor, low contactor coil FC current, and the auxiliary switch is open. This indicates a FC contactor has opened despite being in a closed state.
Clear condition
The HVP detects the FC contactor state as open.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Coil Current
HVP_
|
A |
Neg Ctr Voltage Drop
HVP_
|
V |
Pos Ctr Voltage Drop
HVP_
|
V |
Power Voltage
HVP_
|
V |
| Signal | Unit |
|---|---|
Neg Ctr Aux Open
HVP_
|
— |
Pos Ctr Aux Open
HVP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVP_w040.