Pedal monitor alerts
Browse 97 PM alert codes and open an entry for its description and recorded conditions.
PM alert codes
Showing 51–97 of 97
- PM_a060 — One Pedal Driving Inhibit PM_a060_onePedalDrivingInhibit Pedal Monitor Warning: One Pedal Driving module inhibited.
- PM_a061 — DI PM Version Mismatch PM_a061_DIPMVersionMismatch Pedal Monitor Warning: DI and PM versions do not match.
- PM_a062 — Ecc Error PM_a062_eccError Pedal Monitor Warning: ECC Protection anamoly detected.
- PM_a063 — Torque Command Inhibit PM_a063_torqueCommandInhibit Pedal Monitor Fault: Torque Command Qualifier set to faulted
- PM_a064 — Torque Intervention PM_a064_torqueIntervention Pedal Monitor Warning: Torque Intervention.
- PM_a065 — Brk Tmp Based Cp Est Mismatch PM_a065_brkTmpBasedCpEstMismatch Pedal Monitor Warning: Brake temperatire based Cp estimate mismatch between monitor and control for carbon ceramic brake package
- PM_a066 — Pmf MIA PM_a066_pmfMIA Pedal Monitor Warning: PMF CAN node is missing.
- PM_a067 — Pmr MIA PM_a067_pmrMIA Pedal Monitor Warning: PMR CAN node is missing.
- PM_a068 — Pmrel MIA PM_a068_pmrelMIA Pedal Monitor Warning: PMREL CAN node is missing.
- PM_a069 — Pmrer MIA PM_a069_pmrerMIA Pedal Monitor Warning: PMRER CAN node is missing.
- PM_a070 — Inconsistent Intra Axle Torque PM_a070_inconsistentIntraAxleTorque Pedal Monitor Warning: Intra-axle torque commands are inconsistent.
- PM_a071 — Direl MIA PM_a071_direlMIA Pedal Monitor Warning: DIREL CAN node MIA
- PM_a072 — Direr MIA PM_a072_direrMIA Pedal Warning: DIRER CAN node MIA
- PM_a073 — Can Data Bus C PM_a073_canDataBusC Pedal Monitor Warning: Secondary CAN Integrity Check Failed.
- PM_a074 — Can Hardware Bus C PM_a074_canHardwareBusC Pedal Monitor Warning: CAN hardware error.
- PM_a075 — Can Data Bus D PM_a075_canDataBusD Pedal Monitor Warning: Secondary CAN Integrity Check Failed.
- PM_a076 — Can Hardware Bus D PM_a076_canHardwareBusD Pedal Monitor Warning: CAN hardware error.
- PM_a077 — Can Data Bus E PM_a077_canDataBusE Pedal Monitor Warning: Secondary CAN Integrity Check Failed.
- PM_a078 — Can Hardware Bus E PM_a078_canHardwareBusE Pedal Monitor Warning: CAN hardware error.
- PM_a079 — External Watchdog PM_a079_externalWatchdog Communication between VCLEFT and PM degraded
- PM_a080 — Exception Info0 PM_a080_exceptionInfo0 The Pedal Monitor (PM) detects an unintended processor reset. This alert is intended for logging purposes and does not on its own indicate a symptom or root cause.
- PM_a081 — Exception Info1 PM_a081_exceptionInfo1 The Pedal Monitor (PM) detects an unintended processor reset. This alert is intended for logging purposes and does not on its own indicate a symptom or root cause.
- PM_a082 — Exception Info2 PM_a082_exceptionInfo2 The Pedal Monitor (PM) detects an unintended processor reset. This alert is intended for logging purposes and does not on its own indicate a symptom or root cause.
- PM_a083 — Exception Info3 PM_a083_exceptionInfo3 The Pedal Monitor (PM) detects an unintended processor reset. This alert is intended for logging purposes and does not on its own indicate a symptom or root cause.
- PM_a084 — Exception Info4 PM_a084_exceptionInfo4 The Pedal Monitor (PM) detects an unintended processor reset. This alert is intended for logging purposes and does not on its own indicate a symptom or root cause.
- PM_a085 — Exception Info5 PM_a085_exceptionInfo5 The Pedal Monitor (PM) detects an unintended processor reset. This alert is intended for logging purposes and does not on its own indicate a symptom or root cause.
- PM_a086 — Exception Info6 PM_a086_exceptionInfo6 The Pedal Monitor (PM) detects an unintended processor reset. This alert is intended for logging purposes and does not on its own indicate a symptom or root cause.
- PM_a087 — Can Hardware Bus LIPC PM_a087_canHardwareBusLIPC Pedal Monitor Warning: CAN hardware error.
- PM_a088 — Cccm MIA PM_a088_cccmMIA Pedal Monitor Warning: CCCM CAN node is missing.
- PM_a090 — Excessive Motor Mz PM_a090_excessiveMotorMz Pedal Monitor Warning: Intra-axle torque actuals are excessively large.
- PM_a092 — Xtal Oscillator PM_a092_xtalOscillator Pedal Monitor Warning: Crystal oscillator inactive.
- PM_a093 — Accel Pedal Supply PM_a093_accelPedalSupply Pedal Monitor Warning: Accel pedal Supply out of bounds
- PM_a095 — IT PMS Timeout GNSS Convergence PM_a095_ITPMSTimeoutGNSSConvergence For Development Purposes - Converged absolute tire radii from GNSS RLS estimate during drive cycle
- PM_a096 — IT PMS Converged GNSS Abs Radius Times PM_a096_ITPMSConvergedGNSSAbsRadiusTimes For Development Purposes - Convergence timing information from GNSS RLS estimate during drive cycle
- PM_a097 — IT PMS Relative Calibrated Factors PM_a097_ITPMSRelativeCalibratedFactors For Development Purposes - Convergence values for relative estimate during drive cycle
- PM_a098 — IT PMS Trigger Debug PM_a098_ITPMSTriggerDebug For Development Purposes- Either measured or ITPMS estimate pressure loss has exceeded the allowed threshold
- PM_a099 — IT PMS Calibrated PM_a099_ITPMSCalibrated For Development Purposes - ITPMS feature has been calibrated and will begin estimating pressure loss
- PM_a110 — Indirect T PMS Pressure Loss Warning PM_a110_indirectTPMSPressureLossWarning The Indirect Tire Pressure Monitoring System (ITPMS) estimates the pressure of one or more tires is at least 20% less than the recommended cold pressure.
- PM_a111 — Unintended Reset Caused Neutral PM_a111_unintendedResetCausedNeutral The Pedal Monitor (PM) detects the Drive Inverter (DI) Electronic Control Unit (ECU) resets unexpectedly, causing the vehicle to automatically shift into Neutral.
- PM_a112 — Indirect T PMS Pressure Loss Warning Hard PM_a112_indirectTPMSPressureLossWarningHard The Indirect Tire Pressure Monitoring System (ITPMS) estimates the pressure of one or more tires is less than 25 psi.
- PM_a113 — Btc Monitor PM_a113_btcMonitor Brake traction control monitor tripped.
- PM_a115 — Indirect T PMS Faulted Ghosted PM_a115_indirectTPMSFaultedGhosted The Indirect Tire Pressure Monitoring System (ITPMS) is not operating as expected and cannot detect pressure losses
- PM_a116 — IT PMS Blowout Detected PM_a116_ITPMSBlowoutDetected For Development Purposes - Estimates indicate tire blowout may have occurred
- PM_a117 — IT PMS Permeability Calibrated PM_a117_ITPMSPermeabilityCalibrated For Development Purposes - Permeability calibration debug information
- PM_a120 — Indirect T PMS Faulted PM_a120_indirectTPMSFaulted The Indirect Tire Pressure Monitoring System (ITPMS) is not operating as expected and cannot detect pressure losses
- PM_a125 — Btc Output Irrational PM_a125_btcOutputIrrational Brake Traction Control output is irrational - BTC commands active after monitor trip.
- PM_a126 — Gtw Can Error PM_a126_gtwCanError DIG gateway CAN error: message dropped due to RX queue overflow, TX failure, or gateway forwarding failure.