PM_a067 — Pmr MIA
Full alert identifier: PM_a067_pmrMIA
Alert description
Pedal Monitor Warning: PMR CAN node is missing.
Potential impact
PM system is unable to determine PMR state.
Set condition
The safety monitor sets this condition when CAN communication from PMR is considered irrational or missing.
Clear condition
This alert will clear when PMR CAN data is received.
Signals to check
These diagnostic fields are associated with PM_a067. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
State 4
PM_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PM_a067.