UMC_a008 — Wall Plug OT
Full alert identifier: UMC_a008_wallPlugOT
Message shown in the car
Unable to charge - Wall plug temperature high Wall outlet and wiring inspection recommended
Alert description
UMC wall plug (smart adapter) exceeded temperature threshold
Potential impact
UMC will not allow charging until the smart adapter temperature has fallen sufficiently
Set condition
UMC smart adapter temperature exceeded 75 C or the smart adapter specific rating if present
Clear condition
UMC smart adapter temperature has fallen below 73 C or the smart adapter specific rating if present
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
SA Current
UMC_
|
A |
Wall Plug Temp
UMC_
|
degC |
| Signal | Unit |
|---|---|
SA Region
UMC_
|
— |
Check other alerts