UMC_a008 — Wall Plug OT

Full alert identifier: UMC_a008_wallPlugOT

Message shown in the car

Unable to charge - Wall plug temperature high Wall outlet and wiring inspection recommended

Alert description

UMC wall plug (smart adapter) exceeded temperature threshold

Potential impact

UMC will not allow charging until the smart adapter temperature has fallen sufficiently

Set condition

UMC smart adapter temperature exceeded 75 C or the smart adapter specific rating if present

Clear condition

UMC smart adapter temperature has fallen below 73 C or the smart adapter specific rating if present

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
SA Current UMC_a008_SA_current A
Wall Plug Temp UMC_a008_wallPlugTemp degC
Signal Unit
SA Region UMC_a008_SA_region —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of UMC_a008.