UMC_a010 — Input OT

Full alert identifier: UMC_a010_inputOT

Message shown in the car

Mobile Connector to adapter connection hot Let cool - Plug adapter fully into Mobile Connector

Alert description

UMC input terminals (UMC side of smart adapter connection) exceeded temperature threshold

Potential impact

UMC will not allow charging until input terminals cool sufficiently

Set condition

UMC input terminal temperature has exceeded 95 C

Clear condition

UMC input terminal temperature has fallen below 93 C

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Input Terminals Temp UMC_a010_inputTerminalsTemp degC

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of UMC_a010.