UMC_a010 — Input OT
Full alert identifier: UMC_a010_inputOT
Message shown in the car
Mobile Connector to adapter connection hot Let cool - Plug adapter fully into Mobile Connector
Alert description
UMC input terminals (UMC side of smart adapter connection) exceeded temperature threshold
Potential impact
UMC will not allow charging until input terminals cool sufficiently
Set condition
UMC input terminal temperature has exceeded 95 C
Clear condition
UMC input terminal temperature has fallen below 93 C
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Input Terminals Temp
UMC_
|
degC |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of UMC_a010.