UMC_a007 — Pcba OT
Full alert identifier: UMC_a007_pcbaOT
Message shown in the car
Mobile Connector control box temperature high Let Mobile Connector cool to resume charging
Alert description
UMC PCB temperature exceeded threshold
Potential impact
UMC will not allow charging until the PCB cools off sufficiently
Set condition
UMC PCB temperature exceeded 100 C
Clear condition
UMC PCB temperature has fallen below 98 C
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Pcba Temp
UMC_
|
degC |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of UMC_a007.