UMC_a016 — Pcba OT Foldback

Full alert identifier: UMC_a016_pcbaOTFoldback

Message shown in the car

Mobile Connector control box temperature high Maximum charge rate reduced

Alert description

UMC PCBA temperature is causing output current reduction

Potential impact

UMC will reduce reported current capability by half until the PCBA cools sufficiently

Set condition

UMC PCBA temperature has risen above 90 C

Clear condition

UMC PCBA temperature has fallen below 88 C

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Pcba Temp UMC_a016_pcbaTemp degC

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of UMC_a016.

Browse all UMC alert codes