Skip to content

PCS_a061 — Chg V Line Rationality

Full alert identifier: PCS_a061_chgVLineRationality

Alert description

High DC offset present on charger input voltage sensor when voltage is not expected

Potential impact

Reduced AC charge rate or inability to AC charge

Set condition

Charger line voltage sensor DC offset exceeds threshold for more than five seconds

Clear condition

Charger line voltage sensor DC offset is below clear threshold for more than 500ms

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Chg Input Vdc Offset L 1 L 2 PCS_a061_chgInputVdcOffset_L1L2 V
Chg Input Vdc Offset L 1 N PCS_a061_chgInputVdcOffset_L1N V
Chg Input Vdc Offset L 2 N PCS_a061_chgInputVdcOffset_L2N V
Chg Input Vdc Offset L 3 N PCS_a061_chgInputVdcOffset_L3N V
Signal Unit
Pll Source Irrational L 1 L 2 PCS_a061_PllSourceIrrational_L1L2 —
Pll Source Irrational L 1 N PCS_a061_PllSourceIrrational_L1N —
Pll Source Irrational L 2 N PCS_a061_PllSourceIrrational_L2N —
Pll Source Irrational L 3 N PCS_a061_PllSourceIrrational_L3N —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a061.

Browse all PCS alert codes