PCS_a029 — Chg Power Rationality

Full alert identifier: PCS_a029_chgPowerRationality

Alert description

Charger is unable to meet BMS's requested power

Potential impact

Reduced AC charge rate

Set condition

Charger is unable to meet BMS's requested power within 1kW for more than thirty seconds

Clear condition

Charger is able to meet BMS requested power within 1kW for more than one second

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Bms Power Command PCS_a029_bmsPowerCommand kW
Chg Input Power PCS_a029_chgInputPower kW
Input Vrms PCS_a029_inputVrms V
Signal Unit
Phase Config PCS_a029_phaseConfig —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a029.

Browse all PCS alert codes