PCS_a029 — Chg Power Rationality
Full alert identifier: PCS_a029_chgPowerRationality
Alert description
Charger is unable to meet BMS's requested power
Potential impact
Reduced AC charge rate
Set condition
Charger is unable to meet BMS's requested power within 1kW for more than thirty seconds
Clear condition
Charger is able to meet BMS requested power within 1kW for more than one second
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Bms Power Command
PCS_
|
kW |
Chg Input Power
PCS_
|
kW |
Input Vrms
PCS_
|
V |
| Signal | Unit |
|---|---|
Phase Config
PCS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a029.