Skip to content

PCS_a093 — Power Rail Rationality

Full alert identifier: PCS_a093_powerRailRationality

Alert description

PCS detects one of its logical power rail's measurement becomes irrational

Potential impact

Inability to precharge HV bus, inability to support 12V system, inability to AC charge, inability to drive

Set condition

Power conversion system detects that a logical power rail voltage is outside expected range for more than one second

Clear condition

Power conversion system detects that all logical power rail voltages are within expected range for more than one second

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Power Rail 1 V 2 PCS_a093_powerRail1V2 V
Power Rail 1 V 5 PCS_a093_powerRail1V5 V
Power Rail 3 V 3 PCS_a093_powerRail3V3 V
Power Rail 5 VN PCS_a093_powerRail5VN V
Signal Unit
Irrational 1 V 2 Rail PCS_a093_irrational1V2Rail —
Irrational 1 V 5 Rail PCS_a093_irrational1V5Rail —
Irrational 3 V 3 Rail PCS_a093_irrational3V3Rail —
Irrational 5 VN Rail PCS_a093_irrational5VNRail —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a093.

Browse all PCS alert codes