PCS_a014 — Chg Temp Rationality
Full alert identifier: PCS_a014_chgTempRationality
Alert description
Charger phase temperature is irrational
Potential impact
Reduced AC charge rate or inability to AC charge
Set condition
Charger phase temperature is outside expected range for more than one second
Clear condition
Charger phase temperature is within expected range
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Pha Temperature
PCS_
|
C |
Phb Temperature
PCS_
|
C |
Phc Temperature
PCS_
|
C |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a014.