Skip to content

PCS_a014 — Chg Temp Rationality

Full alert identifier: PCS_a014_chgTempRationality

Alert description

Charger phase temperature is irrational

Potential impact

Reduced AC charge rate or inability to AC charge

Set condition

Charger phase temperature is outside expected range for more than one second

Clear condition

Charger phase temperature is within expected range

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Pha Temperature PCS_a014_phaTemperature C
Phb Temperature PCS_a014_phbTemperature C
Phc Temperature PCS_a014_phcTemperature C

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a014.